HyreSolar

HyreSolar tools

When does your inverter come due?

Finds the year inverter warranty cover ends and how long the panels run on without it, from the dates in your own paperwork.

Checked . Data as of September 5, 2026. HyreSolar sells and installs nothing.

When the inverter warranty ends before the panel warranty, the years between them are the window to plan for. A system switched on in 2019 with a 12-year inverter warranty is covered to 2031, then runs 13 years without inverter cover while a 25-year panel warranty continues. Inverters warranted for 25 years close that gap.

Map your warranty calendar

Figures from your own paperwork. Money outputs stay blank until you enter a real quote, and nothing is stored or emailed.

Example values The filled-in numbers are an example, not your home. Type over them with your own.

Permission-to-operate date, not the contract date.

Off your certificate. We publish no table of manufacturer terms.

The product warranty, not the performance guarantee.

More assumptions (2)

Leave at 0 until you have a real fitted quote. HyreSolar publishes no price.

Only used to express your quote as $/W for comparison.

— Uncovered window
— Inverter cover ends
— Cover remaining
— To set aside each year
— Replacement quote
— Quote as $/W

How this result was worked out

Working it out from the numbers above.

A warranty calendar, not a reliability forecast. Equipment can outlive its warranty.

Your own warranty certificate is the only authority here. HyreSolar does not sell or service inverters.

How to read the coverage gap

The gap is not a prediction that your inverter will fail. It is the number of years in which, if it does fail, the bill is yours. Equipment can outlive its warranty or fail inside it.

What the warranty term tells you is where the manufacturer stopped being willing to carry the risk, which is a useful signal about design life even though it is not a forecast.

Payback models can leave this cost out. A simple payback calculation, ours included, stops at the break-even year and never asks what happens in year 13. If your break-even lands near your warranty cliff, the two numbers are worth looking at together, because a replacement arriving just after break-even resets part of the clock.

A gap of zero is a real answer, not a failure to compute. If your inverter warranty matches or outlasts the panel warranty, you have no uncovered window, and the tool tells you so rather than manufacture a concern.

No gap
Inverter cover runs to or past the panel warranty. Nothing to plan for beyond ordinary monitoring. This is the case with microinverters warranted to match the panels.
Gap of 1 to 8 years
A narrow uncovered window late in the system life. Worth knowing about; not worth acting on early.
Gap above 8 years
A substantial share of the array’s warranted life runs on an out-of-warranty inverter. Here, setting money aside, or pricing an extended warranty while it is still available, earns its keep.

Where to find each number

Where each input comes from, so nothing is a guess.

1. Enter the year the system was switched on

Not the contract date and not the installation date if they differ. Warranty terms can run from commissioning or from purchase, and the difference can be months.

Where to find it: Your permission-to-operate letter from the utility, or the first bill that shows an export credit. See what permission to operate is.

2. Enter your inverter warranty term in years

Read it off the certificate. We do not publish a table of manufacturer terms, because terms vary by model, region and purchase date, and a table would be wrong for many readers.

Where to find it: The inverter warranty certificate in your handover pack, or the manufacturer’s warranty document for your exact model number. The model number is on the label on the unit itself.

3. Check whether an extension was purchased

Some string inverters ship with a shorter standard term that can be extended, sometimes only at installation. If an extension was bought, the certificate shows the extended term: use that.

Where to find it: Your original contract, under equipment or options. An extension bought later, if the manufacturer allows one at all, will have its own paperwork.

4. Enter your panel warranty term

This sets the far edge of the window. It is the product warranty for defects, which is a different thing from the performance guarantee about output.

Where to find it: The panel warranty certificate. Panels can carry two warranties, product and performance, with different lengths. Use the product one here.

5. Enter a replacement quote once you have one

This field starts empty on purpose. HyreSolar does not publish a replacement price, because we could not verify one against a primary source, and a made-up figure is worse than no figure.

Where to find it: Ask your installer, or any local solar service company, what a like-for-like replacement of your specific model would cost fitted. Prices vary by inverter class and by market.

6. Read the sinking-fund figure last

It divides your quote by the years of cover remaining. It is a savings target, not a prediction of when you will spend it.

Where to find it: Nowhere: the tool computes it. Treat it as the amount per year that turns a lump-sum surprise into a planned expense.

How the calculator works it out

  1. 1
    Find the expiry year

    Install year + inverter warranty term. Nothing more sophisticated, because nothing more sophisticated is defensible.

  2. 2
    Count cover remaining

    Expiry year minus the current year. Negative means you are already past it, which the tool says plainly.

  3. 3
    Measure the gap

    Panel warranty term minus inverter warranty term, floored at zero. This is the uncovered window.

  4. 4
    Spread your quote, if you gave one

    Replacement cost ÷ years of cover left. A sinking fund, not a forecast.

The formula, in full. expiry = install year + inverter warranty years. cover remaining = expiry − 2026. gap = max(panel warranty years − inverter warranty years, 0). sinking fund = replacement quote ÷ years of cover remaining.

A worked example, start to finish

A system commissioned in 2019 with a string inverter carrying a 12-year warranty, under panels carrying a 25-year product warranty. The $2,400 replacement quote is hypothetical, used only to show the arithmetic; it is not a market price.

StepValue
System switched on2019
Inverter warranty12 years
Inverter cover ends2031
Cover remaining from 20265 years
Panel product warranty25 years
Uncovered window13 years
Replacement quote entered (hypothetical)$2,400
System size8 kW
Result13 years uncovered, $480/yr to fund it

The array is warranted until 2044. The inverter is warranted until 2031. From 2031 the homeowner owns the replacement risk on a system that still has thirteen years of warranted panel life in front of it.

Setting aside $480 a year for the five remaining covered years turns a $2,400 surprise into a funded line item. At 8 kW that quote is $0.300/W, a useful figure to compare against a second quote for the same unit.

How the answer moves

The same 2019 system, one input changed at a time. Every figure is computed by the calculator on this page.

ChangeCover endsRemaining from 2026Uncovered window
Base case2019 install, 12-year inverter, 25-year panels20315 years left13 years
Microinverters warranted 25 years204418 years leftno gap
String warranty extended to 20 years203913 years left5 years
10-year inverter warranty20293 years left15 years
Installed 2014 instead of 20192026expires this year13 years
Installed 2024 instead of 2019203610 years left13 years
Panels warranted 30 years not 2520315 years left18 years

Note which input actually closes the gap. Moving the install year five years in either direction changes when the cliff arrives but never changes its width: the window stays 13 years.

Only the inverter warranty term closes it: 25-year microinverters take it to zero, a purchased extension to 20 years takes it to five. The gap is decided on the day the equipment is chosen, and by nothing that happens afterwards.

What moves this number most

Ranked, largest first. A proposal can change any of these without saying anything untrue, so check these inputs first.

1. Which inverter class was installed

The inverter’s warranty term, set by the model chosen, is the only input that changes the width of the gap. It is decided at the proposal stage and is effectively permanent afterwards.

2. Whether an extension was bought at installation

Extended inverter warranties can be limited to purchase at or near installation. Years later, that option may have closed. Taking a 12-year term to 20 cuts the window from 13 years to 5.

3. The install year

Moves when the cliff arrives, never how wide it is. Useful for planning, useless for avoiding.

4. The panel warranty term

Sets the far edge. A 30-year panel warranty against a 12-year inverter is an 18-year window, a long uncovered period to discover after signing.

5. What is deliberately absent

Failure rates, mean time to failure, degradation, monitoring hardware, optimizers and the labor share of a replacement. We model the warranty calendar, which is a documented fact about your equipment, rather than a reliability forecast, which is not.

Common mistakes with this calculation

  • Reading the warranty term as a lifespan

    It is neither a promise the unit will last that long nor a prediction it will stop. It is the period the manufacturer is willing to carry the cost. An inverter can run well past it.

  • Using the panel performance warranty instead of the product warranty

    Panels can carry both, and they can be different lengths covering different things. The performance warranty is about output falling below a curve; the product warranty is about defects. Use the product term here.

  • Assuming the installer will still be there

    A warranty claim can run through the installing company, and installers close. If yours has gone, the claim path is the manufacturer directly, which is slower and sometimes narrower. See what to do when your installer is gone.

  • Budgeting the hardware and forgetting the labor

    A replacement quote should be fitted, not supply-only. The unit is one line; the visit, the disconnection, the commissioning and the utility notification are others.

  • Assuming a like-for-like replacement will be available

    Twelve years is a long time in inverter models. A replacement may be a different unit needing different mounting, different comms, or a re-registration with the utility. Ask whether your model is still supported before you assume the swap is simple.

  • Treating a zero gap as nothing to check

    A 25-year inverter warranty is only as good as the company standing behind it in year 20. The term is a contract, not a guarantee of corporate survival.

What this calculator leaves out

The result is a planning estimate. A real proposal accounts for these; this page does not.

  • HyreSolar publishes no inverter replacement price.

    The budget outputs stay blank until you enter a quote you obtained yourself.

  • HyreSolar publishes no table of manufacturer warranty terms.

    Terms vary by model, region and purchase date; read yours off your own certificate.

  • A warranty term is not a failure prediction.

    This tool models a calendar, not reliability.

  • Labor, mounting changes, comms hardware, optimizers and utility re-notification are outside the quote unless your installer put them in it.
  • Warranty start dates vary: commissioning, purchase or shipping.

    If yours is ambiguous, the expiry year may be out by up to a year.

The research behind these numbers

Questions this calculator answers

How long do solar inverters last?
We do not print a lifespan, because a credible one needs a failure distribution for your model and we hold none. What we can tell you is where the manufacturer stopped carrying the risk: the warranty term on your certificate. Ask anyone quoting an average lifespan which dataset it comes from.
Why does the tool not include a replacement price?
We could not verify one against a primary source, and a plausible-looking invented figure would be worse than a blank. Pricing varies by inverter class, model availability and local labor rates. Get a fitted quote for your unit and enter it; the tool then computes your sinking fund and $/W.
What is the coverage gap and why does it matter?
The coverage gap is the years your panels stay under product warranty while your inverter does not. With the example inputs it is 13 years, 2031 to 2044, when an inverter failure is your cost on an otherwise covered system. A proposal may not show it, so this tool does.
Can I still buy an extended inverter warranty?
Possibly not: some extensions are sold only at or near installation, so ask before you sign. A later extension, where offered, may cost more or need an inspection. Our scenario table shows what one buys: taking a 12-year term to 20 years cuts the uncovered window from 13 years to 5.
Do microinverters have no gap?
Where they are warranted for the same term as the panels, the arithmetic gap is zero. That is not the same as no risk: a 25-year warranty depends on the manufacturer still existing in year 24, and it does not cover labor in every case. Read the terms, not the headline number.
My warranty expires this year. What should I do?
Nothing urgent, and not a pre-emptive replacement of a working unit. Check the system is reporting normally, find out whether your model is still supported and stocked, and get a fitted replacement quote now so the number is known before you need it. A working inverter past warranty is a budgeting question.
Does replacing the inverter reset anything?
The new unit carries its own warranty, which can start at its own installation date, so the calendar restarts for that component only. It does not extend your panel warranty, your workmanship warranty or any performance guarantee. If the replacement is a different model, check whether your utility requires re-notification before it is energized.
How does this relate to my payback number?
Simple payback ignores inverter replacement; ours says so in its limits. If your payback lands at year 14 and your warranty cliff at year 12, a replacement may arrive before the system has paid for itself. That makes the simple payback figure optimistic.
What if I do not know when my system was switched on?
Use the date on your permission-to-operate letter from the utility, which is the moment the system was legally allowed to export. If you cannot find it, the first electricity bill showing an export credit brackets it within a month or two. Failing both, your installer or the utility interconnection record will have it.

Sources and methodology

Figures dated September 5, 2026. Last reviewed by the HyreSolar research desk, which writes and checks every tool on this site.

Related solar tools

All 28 solar tools

Your real numbers come from a proposal drawn for your roof, your usage and your utility. Tell us about your home: a person reads it, and nothing goes to a solar company until you agree.

Get Solar Quotes How we check companies